Blue Angel
Dare More Progress!
With these words, the current coalition agreement of the German government is overwritten. For the first time, a coalition agreement is dedicated to the topic of “Sustainability in Digitization”. Accordingly, Data Centers should be:
- Ecologically and sustainably oriented
- Operated in a climate-neutral manner from 2027
- Operated in accordance with the Blue Angel criteria for Data Centers


The Blue Angel for Data Centers
As the German government’s environmental label, Blue Angel has been setting standards for environmentally friendly products and services for more than 40 years. If these standards are taken into account during the planning and design of a Data Center, you can expect to find and implement considerable energy savings. In fact, a Blue Angel-certified Data Center indicates to your customers that it offers environmentally friendly and sustainable services.
As accredited Blue Angel auditors we are not only familiar with its assessment criteria, but we also understand how to ideally set the requirements for air-conditioning, monitoring, and energy supply in the planning process. With Data Center planning from High Knowledge, nothing stands in the way of your data center successfully obtaining Blue Angel certification.
You gain many advantages when planning a Data Center that integrates Blue Angel criteria, including:
- Active climate protection
- Fulfillment of the environmental goals of the German government
- Significant energy cost savings
- Proof of an environmentally conscious and sustainable business model
- Use of the eco-label as a sales and policy instrument
- Fulfillment of the requirements for a sustainable data center in the public sector
Accredited Blue Angel auditors
As accredited Blue Angel auditors, we offer you qualified consulting services that are financially supported by the German government. Blue Angel is structured in the following steps.
In the inventory, our engineers evaluate and analyze all relevant technical systems as part of an initial inspection of the Data Center. The analysis concludes with an explanatory report that provides clear recommendations for action.
- PUE (energy efficient Data Center infrastructure)
- JAZ (energy efficiency of the cooling system)
- MP evu MP ee (power requirements RZ)
- MP it2 (power requirement IT)
- MP ks (current requirement cooling system)
- MP so (electricity requirement other)
- kWh th (cooling load RZ)
- ITEU SV (utilization server)
In the final step, we create all the documents required for the certification process, including:
- IT inventory list servers
- Monitoring energy
- Monitoring IT load
By considering the Blue Angel specifications for data centers, we can develop sustainable as well as ecologically and economically sensible Data Center concepts for you in the planning phase.
Certification process:
Inventory & actual analysis
Consulting concept
Data collection & evidence